15826189997324.jpg

High voltage electromagnetic flowmeter

1. Overview of high voltage electromagnetic flowme
SendInquiry
NoDownload
ProductDetails

ProductIntroduction

1. Overview of high voltage electromagnetic flowmeter products

LDE-RL high voltage electromagnetic flowmeter is a flowmeter based on Faraday's law of electromagnetic induction. It integrates intelligent, small and lightweight integration, multi-function, high precision, high reliability as one of the flow meter products. It can also output 4 to 20mA current signals for recording, adjusting and controlling in the same way as shown in Figure 1.



Two. Characteristics of high voltage electromagnetic flowmeter
1. Strong corrosion resistance. Almost any conductive liquid can be measured.
2, strong anti-interference, almost outside interference.
3. Measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity.
4, there is no pressure loss in the measuring tube, and the requirement of straight pipe section is low.
5. There are no movable parts and no choke components in the pipeline. There is almost no negative pressure loss.
6. Self checking and self diagnosis function.
7. On site, you can modify the range online according to the actual needs of users.
 
Three, high voltage electromagnetic flowmeter lining selection table
Lining materialmain performanceMaximum medium temperatureScope of application
One body typeSeparate type
Polytetrafluoroethylene (PTFE) F4)It is a kind of plastic with very stable chemical properties. It can resist boiling hydrochloric acid, sulfuric acid, nitric acid and aqua regia, and also strong alkali and various organic solvents. It is resistant to corrosion of three fluorine chloride, high temperature three fluorinated chlorine, high velocity liquid fluorine, liquid oxygen and oxygen.70 C100 C 250 C
(special order required)
1, strong acid, alkali and other strong corrosive medium.
2, health media.
Polyfluoroethylene propylene F46)with F4, the resistance to abrasion and negative pressure is higher than that of F4.Ditto
Polyfluorinated ethylene Fs)The upper limit of temperature is lower than that of polytetrafluoroethylene, but the cost is lower.80 C
Polychloroprene rubber1. It has excellent elasticity, high breaking force and good wear resistance.
2, resistance to general low concentration of acid, alkali, salt medium corrosion, do not withstand oxidation medium corrosion.
80 C 120 C
(special order required)
Water, sewage and weakly abrasive slurry.
Polyurethane rubberOne It has excellent wear resistance.80 CNeutral strong wear slurry, coal slurry, mud
Two Corrosion resistance is poor.

Four. Electrode selection form for high voltage electromagnetic flowmeter.
Electrode materialsCorrosion resistance and wear resistance
Stainless steel0Crl8Nil2M02TiIt has weak corrosive media for industrial water, domestic water and sewage. It is suitable for petroleum, chemical, steel and other industrial sectors, municipal, environmental protection and other fields.
Hastelloy alloy BIt has good corrosion resistance to all concentrations of hydrochloric acid below boiling point, and also is resistant to corrosion of non chlorinated acid, alkali and non oxidizing salt solution such as sulfuric acid, phosphoric acid, hydrofluoric acid and organic acid.
Hastelloy alloy CIt can resist the corrosion of non oxidizing acid, such as nitric acid, mixed acid, or the mixture of chromic acid and sulfuric acid, and also oxidizing salts such as: Corrosion of Fc +, Cu + or other oxidants, such as hypochlorite solution above normal temperature, corrosion of seawater.
titaniumResistant to seawater, chloride and hypochlorite, oxidizing acids. (including fuming sulfuric acid), organic acid and alkali corrosion. The corrosion resistance of pure acid (such as sulfuric acid and hydrochloric acid) is not strong, but if the acid contains oxidant (such as nitric acid, Fc +, Cu +), the corrosion will be greatly reduced.
tantalumIt has excellent corrosion resistance and is similar to glass. In addition to hydrofluoric acid, fuming sulphuric acid and alkali, it is almost capable. Corrosion of a chemical medium, including hydrochloric acid at boiling point, nitric acid and sulfuric acid below 50 L. Diao in alkali; corrosion resistance.
Pt / Ti alloyAlmost all chemical media, but not suitable for aqua regia and ammonium salt.
Stainless steel coated tungsten carbideFor non corrosive, strong wear media.
Note: due to the variety of media, its corrosion is affected by complicated factors such as temperature, concentration and velocity. Therefore, this table is for reference only. The user should make his own choice according to the actual situation. If necessary, the decay test of the selected materials should be done, such as hanging film test.

Five, high voltage electromagnetic flowmeter caliper control table
caliber MmFlow range M /hcaliber MmFlow range M /h
DN100.16~2.5DN400Two hundred and fifty ~ 4000
DN150.4~6DN500Four hundred ~ 6000
DN20Zero point six ~ 12DN600Six hundred ~ 10000
DN25One ~ 16DN700Eight hundred ~ 12000
DN321.6~25DN800One thousand ~ 16000
DN40Two point five ~ 40DN900One thousand and two hundred ~ 20000
DN50Four ~ 60DN1000One thousand and six hundred ~ 25000
DN65Six ~ 120DN1200Two thousand and five hundred ~ 30000
DN80Ten ~ 160DN1400Three thousand ~ 50000
DN100Sixteen ~ 250DN1600Three thousand ~ 60000
DN12525~400DN1800Five thousand ~ 60000
DN150Forty ~ 600DN2000Six thousand ~ 100000
DN200Sixty ~ 1000DN2200One thousand three hundred and sixty-seven point seven eight ~ 136778.4
DN250One hundred ~ 1600DN2400One thousand six hundred and twenty-seven point seven eight ~ 162777.6
DN300One hundred and sixty ~ 2500DN2600One thousand nine hundred and ten point three eight~ 191037.6
DN350Two hundred ~ 3000DN28002306.56 ~ 236062.8

Six. High voltage electromagnetic flowmeter selection table.
Modelcaliber
LDE10~2600


Code nameInstallation form
YIntegral type
FSplit type

Code nameConverter type
ZAcircular
ZBSquare (only for split type)

Code namePower supply form
AC(AC) 220V AC 50Hz (90~245V AC 50Hz)
DC(DC) 24V DC (20~36V DC)
LDLithium battery powered (without signal output)

Code name



I



F



Rs



H



C




Medium temperature
Less than 65 degrees centigrade
Less than 120 degrees centigrade
Less than 180 degrees centigrade (only for split type).
Code nameLining material
NEChloroprene rubber (less than 65 degrees Celsius)
PVCPolyvinyl chloride (less than 70 degrees Celsius)
PUPolyurethane wear-resistant (less than 80 degrees Celsius)
PTFEPolytetrafluoroethylene (less than 180 degrees Celsius)

Code nameElectrode material
316LStainless steel
HCHastelloy C
Tititanium
Tatantalum
Ptplatinum
Warm tip: necessary for flowmeter selection, medium, caliber (flow range), electrode material, lining material and installation method.